特點(diǎn)
SphygmoCor 內(nèi)置:全球超過(guò)800篇科研論文(包括臨床驗(yàn)證內(nèi)容),AtCor公司的SphygmoCor技術(shù)是無(wú)創(chuàng)中心動(dòng)脈壓的金標(biāo)準(zhǔn)
運(yùn)動(dòng)容差算法減少再膨脹和錯(cuò)誤讀數(shù)。動(dòng)態(tài)膨脹也會(huì)縮短測(cè)量時(shí)間,并且通過(guò)控制袖帶壓力來(lái)提高病人的舒適度。
順泰醫(yī)療的專(zhuān)利產(chǎn)品Orbit系列的血壓袖帶采用了一個(gè)新穎的拉伸套設(shè)計(jì)來(lái)保持袖帶位置,同時(shí)增進(jìn)病人在整個(gè)24小時(shí)研究?jī)?nèi)的舒適度。
擁有專(zhuān)利的次舒張期波形測(cè)量技術(shù):能為18歲以上的患者提供一個(gè)全功能的生理波形與準(zhǔn)確的增強(qiáng)指數(shù)
AccuWin Pro 4 系統(tǒng)軟件: 模塊化和圖形化,網(wǎng)絡(luò)化的新一代動(dòng)態(tài)血壓縫隙軟件
臨床標(biāo)準(zhǔn)驗(yàn)證:經(jīng)過(guò)世界三大高血壓協(xié)會(huì)的標(biāo)準(zhǔn)驗(yàn)證 BHS,ESH,AAMI
DESCRIPTION
|
ITEM NUMBER
|
Oscar 2? with SphygmoCor Inside
|
99-0133-02
|
Micro USB Cable
|
91-0130-00
|
Oscar 2 Pouch
|
98-0032-07
|
Oscar 2 Belt
|
98-0037-00
|
Oscar 2 User Guide
|
80-0062-00
|
Oscar 2 Quick Start Guide
|
82-0403-00
|
ABPM Cuff, Size 1 (18-26 cm)
|
98-0239-01
|
ABPM Cuff, Size 2 (26-34 cm)
|
98-0239-02
|
ABPM Cuff, Size 3 (32-44 cm)
|
98-0239-03
|
ABPM Cuff, Size 4 (42-55 cm)
|
98-0239-04
|
Technical Specs
SPECIFICATIONS
|
VALUES
|
ABPM Cuff, Size 4 (42-55 cm)
|
98-0063-14
|
ABPM Cuff, Size 3 (32-44 cm)
|
98-0063-13
|
ABPM Cuff, Size 4 (42-55 cm)
|
98-0063-14
|
Method of Measurement
|
Oscillometric with step deflation
|
Blood Pressure Range
|
Systolic: 40-260 mmHg Diastolic: 25-200 mmHg
|
Heart Rate
|
40-200 BPM
|
Maximum
|
280 mmHg
|
Accuracy
|
Heart Rate accurate within +/-2% or +/-3 BPM, whichever is greater. Blood Pressure results meet or exceed ANSI/AAMI/ISO 81060-2:2013 standards for non-invasive accuracy: ±5 mmHg mean error & 8 mmHg standard deviation.
|
Validations
|
Clinically validated to ESH International Protocol, BHS (A/A), and ANSI/AAMI/ISO 81060-2:2013
|
Operating Conditions
|
10°C (50°F) to 50°C (122°F) 20-95% RH non-condensing
|
Ingress Protection
|
Ordinary Equipment, No ingress protection, IPX0.
|
Classification
|
Power: Two (2) AA batteries, continuous operation
|
Data Memory
|
Flash memory stores up to 250 readings
|
Calibration
|
Minimally, once every two years
|
Safety Systems
|
Maximum inflation pressure limited to 300 mmHg; Auto safety release valve for power failure; Maximum measurement time limited to less than 140 seconds
|
Sampling Periods
|
24 independently programmable time periods (Time interval options: none, 5, 10, 15, 20, 30, 45, 60, 90, and 120 minutes)
|
Size
|
Approximately 120 x 70 x 35 mm
|
Weight
|
Approximately 275 g, including batteries
|
Storage
|
-20° C to +70° C, 15%-95% RH non-condensing
|
Data
|
USB 2.0 (Micro USB) with optional BluetoothTM 4.0
|
常見(jiàn)問(wèn)題
-
我怎樣啟動(dòng)/關(guān)閉裝置?
啟動(dòng)時(shí),按住啟動(dòng)/停止按鈕直到您聽(tīng)到連續(xù)3次快速提示音。
關(guān)閉時(shí),按住啟動(dòng)/停止按鈕直到您聽(tīng)到連續(xù)5次快速提示音。
-
Oscar 2動(dòng)態(tài)血壓計(jì)及其電線含有乳膠嗎?
我們的所有產(chǎn)品,包括Oscar 2動(dòng)態(tài)血壓計(jì)、軟管和電線均不含乳膠。
-
收到錯(cuò)誤提示“不能與 ABP 設(shè)備鏈接”,該如何解決?
在配置選項(xiàng)下選擇硬件設(shè)備,然后選擇首選。選擇一種配置進(jìn)行編輯。串行端口將顯示計(jì)算機(jī)上可獲得的所有序列端口。
當(dāng)使用USB適配器時(shí),請(qǐng)先安裝驅(qū)動(dòng)(USB 適配器包中的微型 CD)。
確保Oscar 2動(dòng)態(tài)血壓計(jì)的電池有電。
確保另外的設(shè)備,如 Holter 監(jiān)測(cè)儀或PDA 沒(méi)有連接到特定端口。取下設(shè)備或?qū)scar 2的串行端口更換至可用端口。
確保連接了合適的ABP設(shè)備。更改設(shè)置后,連接ABP,選擇試驗(yàn)端口,確保計(jì)算機(jī)和監(jiān)測(cè)儀已鏈接。